  1. #11
    Join Date
    12-02-2007
    Location
    Corpus Christi, TX
    Posts
    1,011

    Default

    Quote Originally Posted by wesheltonj View Post
    I took some more measurements after making 25 gallons of water today. 188ppm in and 23ppm out. 0 after DI?

    I can increase the water pressure next weekend and see if the number are any better.

    these are good #'s are they not?

  2. #12
    Join Date
    12-09-2006
    Location
    Fair Oaks Ranch, TX
    Posts
    443

    Default

    Looks like according to BFS I can be doing better. Not time today to try, to big of to do list. Looks like next week to increase pressure.
    wesheltonj

    90g Oceanic Reef-Ready Bowfront w/ AquaIllumination LED & GHL Profilux 3eX

  3. #13

    Default

    Quote Originally Posted by DrMark View Post
    these are good #'s are they not?
    Its the RO performance (90% rejection) I'm concerned about. The 0 tds out of the DI is fine.

    So his livestock should be happy, but he may burn through his DI resin faster than we'd like.
    SPONSOR

    RO and RODI Systems and Supplies
    www.BuckeyeHydro.com for all your water purification needs
    Info@BuckeyeHydro.com