UPCOMING: Events

Results 1 to 7 of 7

Thread: Need Help In Sump..

  1. #1
    Join Date
    10-13-2011
    Location
    San Antonio Texas
    Posts
    698

    Default Need Help In Sump..

    So im trying to make some room in my sump..An wanted to see if any one is running one pump on more then one thing..Could i run one pump to my chiller then the chiller to my dual reactor then back to sump..or should i turn the other way around? Any info on this would be good..Or if your running more then that..what an how big of pump..?

  2. #2
    Join Date
    09-10-2007
    Location
    norf side of san antonio
    Posts
    615

    Default

    you could daisy chain, but you'd have more control if you split the output of one pump into two. basically attach a T to your pumps output, add a ballvalve to one or both sides, and run one to your chiller and one to a reactor.

  3. #3

    Default

    Is the chiller on all the time?

    If it isn't, then your reactor would only be in operation when the chiller is...
    ReeF mafiA

  4. #4
    Join Date
    09-10-2007
    Location
    norf side of san antonio
    Posts
    615

    Default

    water runs thru the chiller whether it's chilling or not, my concern was the possibly different flow rates the two things required.

  5. #5
    Join Date
    10-13-2011
    Location
    San Antonio Texas
    Posts
    698

    Default

    Ya the chiller is always on..it need 320..to 340gph..an im not sure on the reactor till i get hm.

  6. #6
    Join Date
    02-06-2010
    Location
    New Braunfels
    Posts
    2,278

    Default Need Help In Sump..

    I have a manifold I made from PVC that supplies my return, two media reactors and I have one extra "line" for another reactor plus a ball valve that goes over to the start (for lack of a better term) of my sump. You basically just need a few T's, a couple 90's and a few ball valves (to control flow). This would let you supply multiple gadgets with one pump and give you control over the pressure or flow each device gets (including your return if you wanted). Your only problem will making sure you have the proper flow through the reactor and chiller. You could do this with a gallon jug or five gallon bucket, a stop watch and some math but it's probably easier said than done. Still, I'd personally rather do that than daisy chain.
    Master Reef Curmudgeon

  7. #7
    Join Date
    03-13-2009
    Location
    doesnt matter
    Posts
    7,459

    Default

    you could always get a manifold or three or four way pvcfittings.com has cool stuff

    http://www.pvcfittings.com/graphics/manifold1.jpg

    http://www.pvcfittings.com/graphics/4ways.jpg
    REEF MAFIA