    I have a 6100 that will run on pulse mode controlled by a 7091 for 30 minutes and then it shut off. I let it cool, plug it in and it works fine again. Im using it in a DIY wavebox.... Any ideas or experiences to share????


    Thanks
    Dustin

  2. #2
    Join Date
    05-05-2005
    Location
    San Antonio, Texas
    Posts
    3,428

    Default

    Thermal shutdown? (Is it overheating?)

    Don't know, just saying.

  3. #3

    Default

    sounds like thermal shut down
    90g mixed reef, 12g nano, 3 dogs, 3 cats, 2 ferrets.
    Driving the wife crazy.......PRICELESS.

  4. #4

    Default

    I got that, but how can I stop it? Is there a part that may be bad? What part? Can I put a fan on the transformer and electrical box to help?


    Thanks
    Dustin

  5. #5

    Default

    Get ahold of Roger on the RC Tunze forum. Although you are using the pump in a 'aftermarket' setup, he may still be able to help you out on replacement parts (if any are required). The fact you are using it in a DIY wavebox will kill any chance of warrenty or free replacements parts though.....

    On a side note, how fast are you running the pulse? Have you considered slowing it down and seeing if the same problem repeats itself?

  6. #6

    Default

    I am running it on the tunze 7091. The pulse time is around 1 sec. I see youtube videos and threads of others doing the same thing, but they arent having the problems I am. I sent Roger a PM yesterday with no reply. I may just try to call him Monday afternoon if I havent heard from him by then.

    Thanks
    Dustin

  7. #7

    Default

    Dustin just take it to Aquatek and let them handle it. Warranty or not, repairing your unit is still the cheapest option.

  8. #8

    Default

    Clint I will get it repaired if needed, Im starting to wounder if maybe this is a controller issue. That controller Tunze uses(6091) on the wavebox shut the pump off completely. The controller Im using only(7091) can only slow the pump down to 30%. I think this may be working the pump to hard, causing the heat issue. Im not running the setup until I get this figured out. I dont wont to cause any damage to the equipment. I have only had it shut off this one time while testing so hopefully someone on here or RC can help....

    Thanks!
    Dustin

  9. #9

    Default

    I would clean the impeller with vinegar, there may be a buildup of deposits impeding the impeller when ramping back up.
    My Reef System: 215g Brick 72x24x29 Dual Overflows | 4x 250w MH | 4x IceCap 39w T5 w/ Actinics | MSX-250 Skimmer | 1/3hp Chiller | 16w UV | Aquacontroller 3 | Lunar Sim | AquaSurf |Tunze Wavebox | 2x Tunze Stream 6101 | MRC Dual Nano Calcium Reactor | GEO Kalk Reactor | Pan World 150PS Pump | Phosban & Carbon Reactors