UPCOMING: Events

Results 1 to 5 of 5

Thread: Sump/Fuge Question

  1. #1

    Default Sump/Fuge Question

    I have an unusual situation. I have a 55 gallon tank converted to a sump, and it is all tempered glass. I have a iwaki 70 external pump that I want to use with this. The partitions in the sump are made of plate glass so they can be drilled. I was wondering if I could plumb a bulkhead near the bottom of the plate glass on the return side to create a constant siphon. here is a poor drawing to give you an idea.

    30L w/10gallon sump 4xt5ho; Up and running:125g long, 30g sump, 50g fuge.

    "Life is tough, but it's tougher when you're stupid.”
    John Wayne

  2. #2
    Join Date
    03-04-2005
    Location
    NE San Antonio
    Posts
    11,696

    Default

    you could, but why do you need a bulkhead? if you ran hard plumbing up and over into the return chamber, it would do the same thing and you wouldnt have to go thru the baffle. you will have difficulty starting the pump because of air in the line, and there is a risk that it will not restart after a power outage if it is run this way (up and over the side of the sump)
    Ace
    The Shade Tree Craftsman



  3. #3

    Default

    That is what I was trying to prevent. If I have it plmbed through the baffle near the bottom, the weight of the water would keep it primed, where as if I have a pipe up and over it will lose prime right? There will be aproximately 15 gallons of water and the tubing will be 3/4 or 1 inch.
    Last edited by coraline79; Sun, 17th Aug 2008 at 09:58 PM.
    30L w/10gallon sump 4xt5ho; Up and running:125g long, 30g sump, 50g fuge.

    "Life is tough, but it's tougher when you're stupid.”
    John Wayne

  4. #4
    Join Date
    03-04-2005
    Location
    NE San Antonio
    Posts
    11,696

    Default

    whether you have a pipe that just runs over the side and ends close to the bottom, or a pipe that goes over and ends close to the bottom thru a baffle, the physics is the same. the water will not push itself over the side of the tank simply because there is more water above the end of the pipe. you will have to manually start the siphon over the side to get to the pump and if that siphon is broken during a power outage for some reason, the pump will not be able to start it again.
    Ace
    The Shade Tree Craftsman



  5. #5

    Default

    Ok, I was just hoping this might resolve it. I think I am just going to have to deal with the siphon until I get a better idea.
    30L w/10gallon sump 4xt5ho; Up and running:125g long, 30g sump, 50g fuge.

    "Life is tough, but it's tougher when you're stupid.”
    John Wayne

Tags for this Thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •