Tue, 3rd Jun 2008, 01:05 AM
#1
Please Review Aquacontroller III Program
I am anticipating my new Aquacontroller III this week and the tank this weekend!!! Got a little bored and thought I would start on the programming.
Can you look at my program for problems or errors?
This will include the base unit, PX 1000 Probe Expansion Module, Lunar Simulator, 2 pH probes, 1 ORP probe, and 2 temp probes. There will be 2 DC8 power strips. Any remaining devices will run off X10 modules.
__________________________________________________ __
ML1 Coralvue 250w Halide
ML2 Coralvue 250w Halide
ML3 Coralvue 250w Halide
ML4 Coralvue 250w Halide
ACT Icecap 660 T5 Ballast
MLS Odyssea 130w PC Light For Frag-Refugium
MON Moon Lights
CHL Current Prime Tower 1/3 HP Chiller
HT1 Heater
HT2 Heater
SK1 MSX Extreme 250 Skimmer Pump 1
SK2 MSX Extreme 250 Skimmer Pump 2
SM1 Mag 18 Pump
WAV Tunze Wavebox
PH2 Koralia 4 PowerHead
PH3 Koralia 3 PowerHead
PH4 Koralia 3 PowerHead
PH5 Koralia Nano PowerHead For Frag-Refugium
PH1 Carbon Phosban Maxijet PowerHead
KST Geo Kalkwasser Reactor Maxijet Powerhead
DP1 Aqualifter ATO Pump To Kalk Reactor
DP2 Aqualifter ATO Pump To Sump
DC1 Dosing Pump Controller 1 Switch
DC2 Dosing Pump Controller 2 Switch
CRC Calcium Reactor Pump
CO2 CO2 Solenoid For Calcium Reactor
ALM Alarm
SOF Sump Feed Switch
__________________________________________________ __
If Sun -120/120 Then ACT ON
If Sun -030/030 Then ML1 ON
If Sun -035/035 Then ML2 ON
If Sun -040/040 Then ML3 ON
If Sun -045/045 Then ML4 ON
If Sun -075/075 Then MLS OFF
If Moon 000/000 Then MON ON
If Timer ACT = ON Then MON OFF
If Temp > 80.4 Then ML1 OFF
Max Change 020 M Then ML1 ON
If Temp > 80.4 Then ML3 OFF
Max Change 020 M Then ML3 ON
If Temp > 80.8 Then ML2 OFF
Max Change 020 M Then ML2 ON
If Temp > 80.8 Then ML4 OFF
Max Change 020 M Then ML4 ON
If Temp > 80.4 Then MLS OFF
Max Change 020 M Then MLS ON
If Temp > 80.8 Then ACT OFF
Max Change 020 M Then ACT ON
If Power 000 Then ML1 OFF
Max Change 020 M Then LT1 ON
If Power 000 Then ML2 OFF
Max Change 023 M Then ML2 ON
If Power 000 Then ML3 OFF
Max Change 026 M Then ML3 ON
If Power 000 Then ML4 OFF
Max Change 029 M Then ML4 ON
If Temp < RT+-0.2 Then HT1 ON
If Temp > RT+0.2 Then HT1 OFF
If Temp < RT+-0.2 Then HT2 ON
If Temp > RT+0.2 Then HT2 OFF
If TmpF < RT+-0.6 Then HT1 ON
If TmpF > RT+0.6 Then HT1 OFF
If TmpF < RT+-0.6 Then HT2 ON
If TmpF > RT+0.6 Then HT2 OFF
If Temp > RT+0.5 Then CHL ON
Max Change 005 M Then CHL ON
If Temp < RT+1.0 Then CHL OFF
Max Change 005 M Then CHL OFF
If Timer SMP = OFF Then CHL OFF
If Time > 00:00 Then ALM OFF
If Time > 00:00 Then SK1 ON
If Time > 00:00 Then SK2 ON
If Time > 00:00 Then SM1 ON
If Time > 00:00 Then WAV ON
If Time > 00:00 Then PH1 ON
If Time > 00:00 Then PH2 ON
If Time > 00:00 Then PH3 ON
If Time > 00:00 Then PH4 ON
If Time > 00:00 Then PH5 ON
If pHf < 06.9 Then CO2 ON
If pHf > 06.7 Then CO2 ON
If pH > 08.40 Then CO2 OFF
If Temp > 81.0 Then ALM ON
If Temp < 78.0 Then ALM ON
If Temf > 81.0 Then ALM ON
If Temf < 78.0 Then ALM ON
If Power 000 Then ALM ON
If pH > 8.5 Then ALM ON
If pH < 7.8 Then ALM ON
If FeedA 000 Then SM1 OFF
If FeedA 000 Then WAV OFF
If FeedA 000 Then SK1 OFF
If FeedA 000 Then SK2 OFF
If FeedA 000 Then PH1 OFF
If FeedA 000 Then PH2 OFF
If FeedA 000 Then PH3 OFF
If FeedA 000 Then CHL OFF
If FeedB 000 Then WAV OFF
If FeedB 000 Then PH2 OFF
If FeedB 000 Then PH3 OFF
If FeedB 000 Then PH4 OFF
If Time > 12:00 Then KAL ON
Max Change 015 M Then KAL OFF
If Time > 23:00 Then KAL ON
Max Change 015 M Then KAL OFF
If Time > 06:00 Then KAL ON
Max Change 015 M Then KAL OFF
If Time > 18:00 Then KAL ON
Max Change 015 M Then KAL OFF
If DC1 = ON THEN DP1 ON
IF DC2 = ON THEN DP1 ON
IF DC1 = ON THEN DP1 ON
IF DC2 = ON THEN DP1 ON
If pH < 7.8 THEN DP1 ON
If pH > 8.4 Then DP2 ON