    Default Ph Controllers - Calcium Reactors

    Questions for those running Calcium Reactors:

    1.) Do you use a controller?
    2.) If so, which one? (in particular - what about the Pinpoint PH controller)
    3.) Thoughts on using one?
    4.) I have an AC JR. but from reading don't think I can use it to control the reactor even though it says it can serve as a controller. Maybe I just haven't figured out how to set it up.

    Thanks reef nuts for help!!

    Lee
    I'm not A.D.D., I'm just . . . Hey look, a squirrel!

    34 Gallon Solana/Current USA 150 HQI & 2 X 65 Watt PC Actinic/(2) 6025Tunze Nanostreams/Koralia Nano/

  2. #2

    Default

    I use a Pinpoint controller on my Korallin reactor. My original idea was to use the probe in the tank water but I later moved the probe to measure the effluent. If my drip line gets clogged, the controller shuts off the CO2 before I melt my reactor media. It's set to turn off at 6.5.

    Does anybody else have any comments about that? Am I doing it right?

    Jack
    Big whorls have little whorls, Which feed on their velocity;
    And little whorls have lesser whorls, And so on to viscosity

    Lewis Richardson in 1922

  3. #3

    Default

    Lee- I have always used the sm122 by milwaukee (never could spell) for my reactors. Its dependable and aforedable, two things i look for when using equipment. Calibrate the probe every 3 months, replace the probe when applicable. Its straight forward.

    Jack, not sure what calcium your using or your ca demand but 6.5 may be too high of a p.H. I run my p.H. around 6.2 and am using aquamedic media (essentially, ARM media). If your monitoring your parameters, than disregard the aformentioned.

    Hope this info helps.

    cheers,

    kurt
    75gal 6x54w t5's on icecap slr's 3 blue +, 1 pro color, 1 ge 65k, 1 uvl spuer atintic, iwaki 40rlt return, mak 4 on closed loop to om super squirt, mak 3 on etss reef devil, jbj artica chiller, aquamedic calcium reactor, DIY Kalk reactor, DIY media reactor, currently running half phospahte/half carbon.

    Live in Uvalde, Texas. On the fish hatchery!

  4. #4
    Join Date
    12-09-2002
    Location
    San Antonio
    Posts
    1,998

    Default

    Lee;
    No, I don't use one, but I think they're a neat idea. Definitely use it to control effluent ph, not tank ph. A cheaper alternative is to get a dwyer flowmeter (RMA151 I think) which is a very precise and stable way of controlling the CO2 flow, then get a GOOD pinch valve to accurately control the effluent drip rate. The ph controller/solenoid arrangement is really only useful to prevent problems caused by the CO2 and/or drip rate fluctuating, which is a rampant problem with most hobby-quality (lousy, that is) CO2 regulators and the cheap airline valves often used to control drip rate.

    I admit, I have a "just okay" regulator and the crappy airline valve, and I'm periodically fiddling with my reactor and using a hand held ph meter to check effluent ph. One of these days I'll straighten up and fly right and get the flowmeter. I used one on a previous reactor and it worked GREAT.