Quote Originally Posted by demodiki View Post
I have a 2.5 year old Water General machine. Six months ago I replaced the RO membrane with a new one. About 2 months ago I changed out my DI resin and also changed the particle filter. Soon after, I was only getting a very light trickle from my system.

I just got in some new resin, carbon blocks and changed all those as well...I thought perhaps my carbon blocks were...blocked! No luck :(

The sink that the system is connected to in the garage still gets great water pressure. I am just not sure what could be wrong. All of my new filters, etc....are from Buckeye Field Supply.

Any thoughts?

You're in a position that a pressure gauge plumbed in the system would have helped you diagnose the problem. If you know that the sediment filter and carbon filter are not clogged, and you know that adequate pressure to run the system is reaching the membrane, then it sounds like the membrane is loaded with scale and needs to be replaced.

Russ