    Larry I had all these GFI Plugs Already, so I chose to just use them. Had I had to buy them you betcha. Would of been 1 per box. $$$ 11.00 A Plug. Ooch! Used 6 all across like this, 2 per box , each has 20 Amp dedicated circuit. If one goes it only effects those two plugs, other wired hot (6 seperate circuits). It is alot of protection can say overkill!! When I bought my house the contractor left a box full of electrical stuff. Freebies I Guess.. Knew I might use them someday.
    Just Lurking around!!!

  2. #12
    Jimnorris Guest

    Default

    Robert,
    WOW what a set up!!!!!!!!!
    Jim

  3. #13

    Default

    If the box has 4 plugs, two double GFCI's with a dedicated 20amp line per box, then you will have to bring the second plug connections from the same side as the incoming wire to have it work like that. Otherwise, if your incoming wires are to one side of the first GFCI and then off the second set of terminals on the other side to the next one, if the first one in the circuit blows, all 4 outlets go off.
    Larry
    INSTAR
    CEO, Biologist
    "Heck, the water is clear, must be good"

  4. #14
    Join Date
    02-18-2004
    Location
    ATX
    Posts
    835

    Default

    Each one is wired to the Hot , Neutral, & Ground. They were installed by a friend of mine( electrician by trade). He had a GFCI Tester I played with it a bit. Each Double plug only trips itself. I Like this better than just one GFCI One trips it all. Thought it be little safer this way in regards to each appliance. I like being able to easily isolate a faulty circuit.

    Robert
    Just Lurking around!!!

  5. #15
    Join Date
    02-18-2004
    Location
    ATX
    Posts
    835

    Default

    New Pics With Unions. Still need 3 More Unions, 2 more bulkheads. Unions made this abit easier to plumb, little more time but worth it I can see. Unions were 1.90 Solvent 4.00 Threaded. Went with solvent. Also fired up the Tunze Stream. Installed the Multi controller W/ One Stream. Look at this Wave!!!! :-D 80% From 40%. Hope the pic shows justice for this. Another will be on the opposite side..

Similar Threads

  1. Help Plumbing Tank
    By ~TG~ in forum General Reefkeeping Discussion
    Replies: 0
    Last Post: Fri, 12th Jan 2007, 11:58 PM
  2. Plumbing a refugium to the main tank?
    By loans_n_fishes in forum Equipment & Do It Yourself
    Replies: 2
    Last Post: Tue, 31st Oct 2006, 05:30 PM
  3. Plumbing Done!! New tank- Diary
    By C.Mydas in forum General Reefkeeping Discussion
    Replies: 14
    Last Post: Wed, 30th Aug 2006, 08:34 AM
  4. Plumbing tape & CO2 tank?
    By TexasState in forum General Reefkeeping Discussion
    Replies: 15
    Last Post: Wed, 18th Feb 2004, 04:12 PM
  5. Plumbing For Tank
    By manny in forum General Reefkeeping Discussion
    Replies: 19
    Last Post: Thu, 5th Feb 2004, 10:08 PM

Tags for this Thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •