    Default Ro/Di Help

    I have a 2.5 year old Water General machine. Six months ago I replaced the RO membrane with a new one. About 2 months ago I changed out my DI resin and also changed the particle filter. Soon after, I was only getting a very light trickle from my system.

    I just got in some new resin, carbon blocks and changed all those as well...I thought perhaps my carbon blocks were...blocked! No luck :(

    The sink that the system is connected to in the garage still gets great water pressure. I am just not sure what could be wrong. All of my new filters, etc....are from Buckeye Field Supply.

    Any thoughts?
    Danny
    90 gallon softies and lps
    bad bassett hound
    Large Doberman

  2. #2
    Join Date
    07-04-2006
    Location
    Now serving in Round Rock, TX.
    Posts
    1,851

    Default

    My guess would be that your first set of filters may have been broke or not of good quality. I hear this a lot from people that have RO systems, at first I was guilty as well. In perspective let's think that most systems are 75gpd. That really is a trickle. The math to support. 60 minutes in an hour x 24 hours in a day= 1,440 minutes in a day / 75gpd = 19.2 What that means is that a typical system takes 20 minutes to produce 1 clean gallon of water. That is just a trickle. It would take almost an hour and half to fill a 5g container. If your membrane was torn water may have been blowing right on by and into the resin chamber. There is nothing in that chamber to cause it to slow down. Your resins could still absorb the excess TDS until spent, thus giving a true reading of 0-4PPM of TDS until exhausted.

  3. #3
    Join Date
    10-18-2002
    Location
    New Braunfels
    Posts
    4,358

    Default

    I have the same problem right now and I have determined that too much chloramine in the water has clogged up my new RO unit and will have to buy another carbon filter to help remove chlorine from water
    My Reef is Alive and well Despite My repeated Daily attemps to kill it!!

  4. #4

    Default

    Quote Originally Posted by demodiki View Post
    I have a 2.5 year old Water General machine. Six months ago I replaced the RO membrane with a new one. About 2 months ago I changed out my DI resin and also changed the particle filter. Soon after, I was only getting a very light trickle from my system.

    I just got in some new resin, carbon blocks and changed all those as well...I thought perhaps my carbon blocks were...blocked! No luck :(

    The sink that the system is connected to in the garage still gets great water pressure. I am just not sure what could be wrong. All of my new filters, etc....are from Buckeye Field Supply.

    Any thoughts?

    You're in a position that a pressure gauge plumbed in the system would have helped you diagnose the problem. If you know that the sediment filter and carbon filter are not clogged, and you know that adequate pressure to run the system is reaching the membrane, then it sounds like the membrane is loaded with scale and needs to be replaced.

    Russ