View Full Version : is there?
sly fox
Wed, 30th Apr 2008, 04:56 PM
such a thing as a 1/2" wye that reduces to 2x 3/4" outlets?
thx
SaltyJim
Wed, 30th Apr 2008, 05:17 PM
Did you mean 1 1/2" to 2x 3/4" reducing? I have never seen a wye with that config, but it may exist. Most wye's that I have seen have two inlets of the larger size, and one of the smaller. To get the other configuration as you had listed, use a 3/4" to 1/2" reducing tee with some 45deg adapters.
captexas
Wed, 30th Apr 2008, 05:41 PM
try looking on www.savko.com (http://www.savko.com)
They have lots of plumbing supplies
LoneStar
Wed, 30th Apr 2008, 06:10 PM
Yeah it can easily be made with reducing bushings and tee's but I don't think you will find the exact wye in question.
BTW Savko is an awesome site. Best place to buy true union ball valves dirt cheap.
sly fox
Wed, 30th Apr 2008, 06:49 PM
thanks guys... yep i meant 1 1/2 to 3/4... trying to plumb my cube, and want to use 2 hydor flo's on the return, so need to split it ... thanks for the suggestions
Bill S
Wed, 30th Apr 2008, 06:53 PM
Just remember, 3/4 + 3/4 in plumbing does NOT = 1-1/2.
1.5 squared = 2.25
3/4 squared = .56.
That means a 1-1/2 carries over 4X the flow that each 3/4" carries (without friction, which makes it an even BIGGER difference). 1" on the other hand, is closer.
sly fox
Wed, 30th Apr 2008, 07:29 PM
thanks... well i have overkill as a pump, a reeflo snapper, which cranks down, was going to put in a gate to reduce flow with... do you think i'll have problems? unf the hydor flos fit 3/4"... the plan is to have 2 coming out of the front of a diy rock tree, hence reducing the need for powerheads (its a 25g cube) and having good water flow... just trying to do something different... any other suggestions as to what i could use instead of the hydo flos?
JLiu
Wed, 30th Apr 2008, 07:40 PM
Sheesh turning the tank over 100X is nice wouldn't have to worry about stirring anything up. :) Have you thought about a return manifold to utilize the pump more versus the hydors?
SaltyJim
Wed, 30th Apr 2008, 08:00 PM
another place to check for some specialty fitting is http://pvcfittings.com/. They have a 1 1/2" to 2x 1" wye that may work for you.
sly fox
Wed, 30th Apr 2008, 08:12 PM
thanks guys... the tank is a rimless cube, so id be worried that a return manifold would mess up the aesthetics, it will also be coverless, with a sunpod suspended above it..
great pvc place link by the way..
sly fox
Wed, 30th Apr 2008, 08:17 PM
ah....could i do a return manifold instead of around the top of the tank insidethe trunk? is that what you meant? now ifthat works that would be possible
sly fox
Mon, 5th May 2008, 02:51 PM
well, i decided to use a different pump, so can do the whole thing in 1" pvc...makes it easier...