View Full Version : RO/DI Mounting - head pressure?



Bill S
Tue, 7th Feb 2006, 10:08 AM
Can I mount my new-to-me (second) RO/DI unit under my wet bar, and then run the water line up 7 feet to a storage tank? Is the head pressure for it simply a result of my 35 psi input pressure? The one on my sink is about 3 feet higher than the unit...

Thanks!

brewercm
Tue, 7th Feb 2006, 11:59 AM
It will make it up 7 feet with no problem. Not sure on the head pressure on an outlet of one but sure it will go that easily.

GaryP
Tue, 7th Feb 2006, 12:14 PM
Head pressure is roughly 1/2 pound per foot. So, 3 ft. would be 1.5 psi. The product outlet pressure is not very high though. I think most of the pressure goes to the drain.

brewercm
Tue, 7th Feb 2006, 12:29 PM
The only reason I said it should make it easily is mine went about 6 feet when I initially filled my tank and it ran great. Not sure of my inlet pressure though on my setup, it supplies my drinking water and also auto topoff of my sump (greatest thing I ever did).

Bill S
Tue, 7th Feb 2006, 02:35 PM
Thanks, guys. I didn't want to install it and then find out it wouldn't work! Now, if I could just decide, overflows, or calfo....

jroescher
Tue, 7th Feb 2006, 11:15 PM
The pressurized tanks for RO storage carry 4 to 6 pounds of air pressure. So I would imagine that as long as you didn't exceed that by too much, head pressure shouldn't be a problem.