Just bought a new one of these and it didnt come with instructions.

It has two inlets and two outlets.
Can someone check their system and get me a simple diagram.
It said on the website I needed a check valve,so I have that too.


I want to install it between my RO/DI unit and the water storage tank, which has a float valve on it.

Thanks everyone.

rocketeer
Sat, 20th Aug 2005, 10:58 PM
Hi,

I found this...

You want the valve to shut off the water going to the RO/DI unit. That way the waste water stops too. The other two ports make a pressure difference sensor. Difference in pressure makes the valve open. No difference in pressure makes the valve shut.

Your valve is labeled ASO Valve in the diagram. I really like using a bladder tank, but you probably don't need one.

Jack